1GR-FE (V6)
O2S TEST RESULT CHART
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value |
|---|---|---|---|---|
| $81 | Percentage of monitoring time when the O2S voltage is less than 0.05V | Multiply 0.3906 | % | Within 60 % |
TID $07: A/F SENSOR HEATER
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.00017 (A) | Maximum A/F sensor heater current (bank 1) | Malfunction criterion |
| 1 | $10 | Multiply by 0.00017 (A) | Maximum A/F sensor heater current (bank 2) | Malfunction criterion |
TID $04: HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $02 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 2) | Malfunction criterion |
| 1 | $20 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 2 sensor 2) | Malfunction criterion |
TID $08: THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT reaches malfunction criterion - | Malfunction criterion |
O2S TEST RESULT (MODE 05)
| Test ID/Comp ID | Description of Test Date | Conversion Factor | Unit |
|---|---|---|---|
| $07 | The minimum sensor voltage while the malfunction is being monitored | N/A | V |
| $08 | The maximum sensor voltage while the malfunction is being monitored | N/A | V |
HEATED OXYGEN SENSOR
| Test ID/Comp ID | Description of Test Data | Conversion Factor | Unit |
|---|---|---|---|
| $81 | Percentage of monitoring time where heated oxygen sensor voltage is less than 0.05 V | Multiply 0.3906 | % |
| $84 | Percentage of monitoring time where heated oxygen sensor voltage is 0.70 V or more | Multiply 0.3906 | % |
| $85 | Maximum Rich (0.45 V or more) time | Multiply 0.2621 | second |
TID $01: Catalyst - Using A/F Sensor and HO2S
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 no dimension | Catalyst deterioration level bank 1: Determined by waveform of A/F sensor and HO2S | Malfunction criterion |
| 0 | $02 | Multiply by 0.0078 (no dimension) | Catalyst deterioration level bank 2: Determined by waveform of A/F sensor and HO2S | Malfunction criterion |
TID $02: EVAP - LEVII VACUUM MONITOR
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.183 (mmHg) Test value of EVAP VSV stuck closed: Determined by fuel tank pressure change during vacuum introduction | Malfunction criterion | |
| 0 | $02 | Multiply by 0.0655 (Seconds) | Test value of EVAP VSV stuck open: Determined by abnormal state continuation time | Malfunction criterion |
| 0 | $030 | Multiply by 0.0655 (Seconds) | Test value of canister closed valve (CCV): Determined by abnormal state continuation time | Malfunction criterion |
| 0 | $04 | Multiply by 0.0458 (mmHg) | Test value of 0.04 inch leak: Determined by fuel tank pressure change | Malfunction criterion |
| 0 | $05 | Multiply by 0.0458 (mmHg) | Test value of 0.02 inch leak: Determined by fuel tank pressure change | Malfunction criterion |
TID $06: A/F SENSOR
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.000244 (No dimension) | Parameter for identify A/F sensor response rate bank 1 | Malfunction criterion |
| 0 | $11 | Multiply by 0.000244 (No dimension) | Parameter for identify A/F sensor response rate (bank 2) | Malfunction criterion |