FixVault

1ZZ-FE 1.8L

TID $04: HO2S Heater

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 (A) Maximum HO2S heater current (bank 1 sensor 1) Malfunction criterion
1 $02 Multiply by 0.000076 (A) Maximum HO2S heater current (bank 1 sensor 2) Malfunction criterion
TID $08: Thermostat

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT reaches malfunction criterion Malfunction criterion
FRONT O2S TEST RESULT - (BANK 1 SENSOR 1)

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value of TEST LIMIT
$07 Minimum front HO2S voltage N/A V Between 0 and 0.4 V
$08 Maximum front HO2S voltage N/A V Between 0.55 and 1.275 V
Front HO2S slow response

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value of TEST LIMIT
$31 Time to change from Lean (less than or equal to 0.4 V) to Rich (greater than or equal to 0.55 V) N/A sec. Between 0 and 1 sec.
$32 Time to change from Rich (greater than or equal to 0.55 V) to Lean (less than or equal to 0.4 V) N/A sec. Between 0 and 1 sec.
Rear HO2S voltage monitor

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value of TEST LIMIT
$07 Minimum rear HO2S voltage N/A V Between 0 and 0.4 V
$08 Maximum rear HO2S voltage N/A V Between 0.5 and 1.275 V
REAR HO2S ELEMENT MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value of TEST LIMIT
$81 Percentage of monitoring time when the HO2S voltage is less than 0.05 V Multiply 0.3906 % Between 0 and 60 %
$84 Percentage of monitoring time when the HO2S voltage is more than 0.7 V Multiply 0.3906 % Between 20 and 100 %
$85 Time when the HO2S voltage is 0.45 V or more Multiply 0.2621 sec. Between 20 and 66.8 sec.
TID $01: Catalyst- Using Front HO2S and Rear HO2S

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level bank 1 : Determined by waveform of front HO2S and rear HO2S Malfunction criterion
TID $02: EVAP - Vacuum Monitor

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.0916 (mmHg) Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction Malfunction criterion
1 $02 Multiply by 0.0458 and subtract 2.93 (mmHg) Test value of bypass VSV (pressure switching valve) and CCV: Determined by fuel tank pressure change at switching over bypass VSV and CCV Malfunction criterion
0 $03 Multiply by 0.0458 (mmHg) Test value of 0.04 inch leak: Determined by fuel tank pressure change Malfunction criterion
0 $04 Multiply by 0.0458 (mmHg) Test value of 0.02 inch leak: Determined by fuel tank pressure change Malfunction criterion