Service Data
2AZ-FE:
Emission Control Service Data (2AZ-FE)
| VSV for CCV | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 40 Ω | |
| VSV for EVAP | ||
| Resistance | 1 -- 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 -- Body ground | 10 kΩ or higher | |
| 2 -- Body ground | 10 kΩ or higher | |
| Air fuel ratio sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 0.8 to 1.4 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 1.8 to 3.2 Ω at 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 1 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 Ω at 800°C (1,472°F) | |
3MZ-FE:
Emission Control Service Data (3MZ-FE)
| VSV for CCV | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 40 Ω | |
| VSV for EVAP | ||
| Resistance | 1 -- 2 | 26 to 30 Ω at 20°C (68°F) |
| 1 -- Body ground | 10 kΩ or higher | |
| 2 -- Body ground | 10 kΩ or higher | |
| Air fuel ratio sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 0.8 to 1.4 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 1.8 to 3.2 Ω at 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 1 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 Ω at 800°C (1,472°F) | |
| Heated oxygen sensor (Bank 2 Sensor 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 2 (+B) | 23 to 32 Ω at 800°C (1,472°F) | |