Terminals Of ECM
Pulse generation 1
Reference:
ITEM AND CONDITION (PULSE GENERATION 1)
| Item | Condition |
|---|---|
| Terminal | SLT+ - SLT- |
| Tool setting | 5V/DIV, 1ms/DIV |
| Vehicle condition | Engine idle speed |
Pulse generation 2
Reference:
ITEM AND CONDITION (PULSE GENERATION 2)
| Item | Condition |
|---|---|
| Terminal | SLU+ - SLU- |
| Tool setting | 5V/DIV, 1ms/DIV |
| Vehicle condition | Engine idle speed |
Pulse generation 3
Reference:
ITEM AND CONDITION (PULSE GENERATION 3)
| Item | Condition |
|---|---|
| Terminal | SL2+ - SL2- |
| Tool setting | 5V/DIV, 1ms/DIV |
| Vehicle condition | Engine idle speed |
Pulse generation 4
Reference:
ITEM AND CONDITION (PULSE GENERATION 4)
| Item | Condition |
|---|---|
| Terminal | SL1+ - SL1- |
| Tool setting | 5V/DIV, 1ms/DIV |
| Vehicle condition | Engine idle speed |
Pulse generation 5
Reference:
ITEM AND CONDITION (PULSE GENERATION 5)
| Item | Condition |
|---|---|
| Terminal | NT+ - NT- |
| Tool setting | 1V/DIV, 2ms/DIV |
| Vehicle condition | Engine idle speed |
Pulse generation 6
Reference:
ITEM AND CONDITION (PULSE GENERATION 6)
| Item | Condition |
|---|---|
| Terminal | SP2+ - SP2- |
| Tool setting | 2V/DIV, 20ms/DIV |
| Vehicle condition | Vehicle speed 20 km/h (12 mph) |