FixVault

Terminals Of ECM

Fig 1: Identifying ECM Terminals
G03070215Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 2: ECM Terminals Voltage Table
G03070216Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 1

Reference: 

ITEM AND CONDITION (PULSE GENERATION 1)

Item Condition
Terminal SLT+ - SLT-
Tool setting 5V/DIV, 1ms/DIV
Vehicle condition Engine idle speed
Fig 3: Signal Waveform Graph (Pulse Generation 1)
G03070217Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 2

Reference: 

ITEM AND CONDITION (PULSE GENERATION 2)

Item Condition
Terminal SLU+ - SLU-
Tool setting 5V/DIV, 1ms/DIV
Vehicle condition Engine idle speed
Fig 4: Signal Waveform Graph (Pulse Generation 2)
G03070218Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 3

Reference: 

ITEM AND CONDITION (PULSE GENERATION 3)

Item Condition
Terminal SL2+ - SL2-
Tool setting 5V/DIV, 1ms/DIV
Vehicle condition Engine idle speed
Fig 5: Signal Waveform Graph (Pulse Generation 3)
G03070219Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 4

Reference: 

ITEM AND CONDITION (PULSE GENERATION 4)

Item Condition
Terminal SL1+ - SL1-
Tool setting 5V/DIV, 1ms/DIV
Vehicle condition Engine idle speed
Fig 6: Signal Waveform Graph (Pulse Generation 4)
G03070220Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 5

Reference: 

ITEM AND CONDITION (PULSE GENERATION 5)

Item Condition
Terminal NT+ - NT-
Tool setting 1V/DIV, 2ms/DIV
Vehicle condition Engine idle speed
Fig 7: Signal Waveform Graph (Pulse Generation 5)
G03070221Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Pulse generation 6

Reference: 

ITEM AND CONDITION (PULSE GENERATION 6)

Item Condition
Terminal SP2+ - SP2-
Tool setting 2V/DIV, 20ms/DIV
Vehicle condition Vehicle speed 20 km/h (12 mph)
Fig 8: Signal Waveform Graph (Pulse Generation 6)
G03070222Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002