FixVault

Monitor Strategy

MONITOR STRATEGY SPECIFICATION TABLE

Related DTCs P0101: Mass air flow meter rationality
Required sensors/ components (Main) Mass air flow meter
Required sensors/ components (Related) Crankshaft position sensor, engine coolant temperature sensor and throttle position sensor
Frequency of operation Continuous
Duration 10 seconds (high voltage) 6 seconds (low voltage)
MIL operation 2 driving cycles
Sequence of operation None