Monitor Strategy

MONITOR STRATEGY

Related DTCs P0420: Bank 1 catalyst is deterioration
Required sensors/components Main:
Required sensors/components A/F sensor, heated oxygen sensor
Required sensors/components Related:
Required sensors/components Mass air flow meter, engine coolant temperature sensor, engine speed sensor, intake air temperature sensor
Frequency of operation Once per driving cycle
Duration 30 seconds
MIL operation 2 driving cycles
Sequence of operation None