FixVault

Monitor Strategy

MONITOR STRATEGY SPECIFICATION TABLE

Related DTCs P0101: MAF Meter Rationality (Low voltage)
P0101: MAF Meter Rationality (High voltage)
Required sensors / components (Main) MAF meter
Required sensors / components (Related) Crankshaft position sensor, ECT sensor, Throttle position sensor
Frequency of operation Continuous
Duration 10 seconds
MIL operation 2 driving cycles
Sequence operation None