HOW TO READ O2S TEST RESULT USING hand-held TESTER
- Connect the hand-held tester to the DLC3.
- On the tester screen, select the following menus: DIAGNOSIS / CARB OBDII / O2S TEST RESULT. A list of the O2S equipped on the vehicle will be displayed.
- Select the desired O2S and press ENTER. The following screen will appear.
- Press HELP and * simultaneously. More information will appear.
- Example:
- The hand-held tester displays "17" as a value of the "TIME $81" (see the illustration on the left).
- Find the Conversion Factor value of "TIME $81" in the O2S TEST RESULT chart below. 0.3906 is specified for $81 in this chart.
- Multiply "17" in step (1) by 0.3906 (Conversion Factor) in the step (2).
17 x 0.3906 = 6.6%
- If the answer is within the standard value, the "TIME $81" can be confirmed to be normal.
O2S TEST RESULT Chart
O2S TEST RESULT CHARTTEST ID Description of TEST DATA Conversion Factor Unit Standard Value $81 Percentage of monitoring time when the HO2S voltage is less than 0.05V Multiply 0.3906 % Within 60%