FixVault

HOW TO READ O2S TEST RESULT USING hand-held TESTER

  1. Connect the hand-held tester to the DLC3.
    Fig 1: O2S TEST RESULT - Hand-Held Tester Display
    G02647667Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. On the tester screen, select the following menus: DIAGNOSIS / CARB OBDII / O2S TEST RESULT. A list of the O2S equipped on the vehicle will be displayed.
    Fig 2: TEST DATA Screen - Hand-Held Tester Display
    G02647668Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. Select the desired O2S and press ENTER. The following screen will appear.
  4. Press HELP and * simultaneously. More information will appear.
  5. Example:
    1. The hand-held tester displays "17" as a value of the "TIME $81" (see the illustration on the left).
    2. Find the Conversion Factor value of "TIME $81" in the O2S TEST RESULT chart below. 0.3906 is specified for $81 in this chart.
    3. Multiply "17" in step (1) by 0.3906 (Conversion Factor) in the step (2).

      17 x 0.3906 = 6.6% 

    4. If the answer is within the standard value, the "TIME $81" can be confirmed to be normal.

    O2S TEST RESULT Chart 

    O2S TEST RESULT CHART

    TEST ID Description of TEST DATA Conversion Factor Unit Standard Value
    $81 Percentage of monitoring time when the HO2S voltage is less than 0.05V Multiply 0.3906 % Within 60%