FixVault

Monitor Strategy

MONITOR STRATEGY REFERENCE

Related DTCs P0101: Mass air flow meter rationality
Required Sensors / Components (Main) Mass air flow meter
Required Sensors / Components (Related) Crankshaft position sensor, engine coolant temperature sensor and throttle position sensor
Frequency of Operation Continuous
Duration 10 seconds
MIL Operation 2 driving cycles
Sequence of Operation None