Combination Meter: Inspection
- LIGHT CONTROL RHEOSTAT
- Inspect continuity.
- Check the continuity between the light control rheostat connector terminals when operating the rheostat volume knob.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard:
LIGHT CONTROL RHEOSTAT - CONTINUITY TABLESwitch Tester connection (Symbol) Condition Turn the knob to maximum 1 (TC) - 4 (T) Below 1 Ω Conditions other than the above 1 (TC) - 4 (T) 10 kΩ or higher - Check the continuity between the light control rheostat connector terminals when operating the rheostat volume knob.
- Check the resistance between terminal 3 (RV) and terminal 4 (T) when operating the light control rheostat volume knob. Also, check that the resistance changes continuously.
Standard:
Turn the knob to maximum: Approx. 10 kΩ
Turn the knob to minimum: Approx. 0 kΩ
- Inspect continuity.