FixVault

Speed Sensor: Inspection

  1. INSPECT TRANSMISSION REVOLUTION SENSOR (NT) 
    1. Disconnect the sensor connector from the transmission.
    2. Measure the resistance of the sensor.

      Standard resistance 

      TERMINALS RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω
      Fig 1: Identifying Transmission Revolution Sensor (NT) Connector
      G04436536Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT TRANSMISSION REVOLUTION SENSOR (SP2) 
    1. Disconnect the sensor connector from the transmission.
    2. Measure the resistance of the sensor.

      Standard resistance 

      TERMINALS RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω
      Fig 2: Identifying Transmission Revolution Sensor (SP2) Connector
      G04436537Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002