FixVault

Deceleration Sensor: Installation

  1. INSTALL DECELERATION SENSOR 
    1. Install the 2 bolts and deceleration sensor to the body, then connect the deceleration sensor connector to the deceleration sensor.

      Torque: 21 N*m (214 kgf*cm, 15 ft.*lbf) 

      NOTE:
      • Do not use the dropped or damage sensor.
      • Free from the foreign matters or floor carpet between the deceleration sensor bracket and body.
        Fig 1: Installing Deceleration Sensor
        G04465373Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSTALL YAW RATE SENSOR BRACKET 
    1. Install the bolt and upper side deceleration sensor bracket.

      Torque: 21 N*m (214 kgf*cm, 15 ft.*lbf) 

    Fig 2: Installing Yaw Rate Sensor Bracket
    G04465374Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSTALL FRONT SEAT ASSEMBLY LH (See  INSTALLATION  ) 
  4. CHECK DECELERATION SENSOR SIGNAL 

    HINT:

    See TEST MODE PROCEDURE