FixVault

Air Conditioning: Condenser: Reassembly

  1. INSTALL COOLER DRYER 
    1. Using pliers, install the cooler dryer.
      Fig 1: Installing Cooler Dryer
      G04465821Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Install a new O-ring to the cap.
    3. Sufficiently apply compressor oil to the fit surfaces of the O-ring and the cap.

      Compressor oil: 

      ND-OIL 8 or equivalent 

      Fig 2: Installing O-Ring To Cap
      G04465822Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Using a socket hexagon wrench 14 mm (0.55 in.), install the cap to the modulator.

      Torque: 2.9 N*m (29 kgf*cm, 25 in.*lbf) 

      Fig 3: Installing Cap To Modulator
      G04465823Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002