Inspection Procedure
NOTE:
When replacing the ABS and TRACTION actuator assembly, perform zero point CALIBRATION
.
- CHECK DTC
B: REPAIR CIRCUIT INDICATED BY OUTPUT DTC
A: GO TO NEXT STEP
- INSPECT SKID CONTROL ECU CONNECTOR SECURELY CONNECTED
- Check the ECU connector's connecting condition.
OK: The connector should be securely connected.
NG: CONNECT CONNECTOR TO ECU CORRECTLY
OK: GO TO NEXT STEP
- Check the ECU connector's connecting condition.
- INSPECT BATTERY
- Check the battery voltage.
Standard voltage: 11 to 14 V
NG: INSPECT CHARGING SYSTEM
OK: GO TO NEXT STEP
- Check the battery voltage.
- INSPECT SKID CONTROL ECU (IG1 TERMINAL)
- WHEN USING INTELLIGENT TESTER:
- Connect the intelligent tester to the DLC3.
- Start the engine.
- Select the DATA LIST mode on the intelligent tester.SKID CONTROL ECU (IG1 TERMINAL) (USING INTELLIGENT TESTER)
Item Measurement Item / Range (Display) Normal Condition IG VOLTAGE ECU power supply voltage / TOO LOW / NORMAL / TOO HIGH TOO LOW: 9.5 V or less
NORMAL: 9.5 to 14.0 V
TOO HIGH: 14.0 V or more - Check the voltage condition output from the ECU displayed on the intelligent tester.
OK: "Normal" is displayed.
- WHEN NOT USING INTELLIGENT TESTER:
- Disconnect the skid control ECU connector.
- Turn the ignition switch to the ON position.
- Measure the voltage according to the value(s) in SKID CONTROL ECU (IG1 TERMINAL) (WHEN NOT USING INTELLIGENT TESTER)
.
Standard voltage
SKID CONTROL ECU (IG1 TERMINAL) (WHEN NOT USING INTELLIGENT TESTER)Tester Connection Condition Specified Condition S1-46 (IG1) - Body ground IG switch ON 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (IG1 CIRCUIT)
OK: GO TO NEXT STEP
- WHEN USING INTELLIGENT TESTER:
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)
- Disconnect the skid control ECU connector and combination meter connector.
- Measure the resistance according to the value(s) in SKID CONTROL ECU - COMBINATION METER (1 OF 2)
.
Standard resistance
SKID CONTROL ECU - COMBINATION METER (1 OF 2)Tester Connection Specified Condition C18-1 - S1-36 (VSCW) Below 1 Ω - Measure the resistance according to the value(s) in SKID CONTROL ECU - COMBINATION METER (2 OF 2)
.
Standard resistance
SKID CONTROL ECU - COMBINATION METER (2 OF 2)Tester Connection Specified Condition S1-36 (VSCW) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO TO NEXT STEP
- INSPECT SKID CONTROL ECU (GND TERMINAL)
- Disconnect the skid control ECU connector.
- Measure the resistance according to the value(s) in SKID CONTROL ECU (GND TERMINAL)
.
Standard resistance
SKID CONTROL ECU (GND TERMINAL)Tester Connection Specified Condition S1-32 (GND1) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (GND CIRCUIT)
OK: GO TO NEXT STEP
- INSPECT COMBINATION METER ASSEMBLY
- Check combination meter assembly (See HOW TO PROCEED WITH TROUBLESHOOTING ).
NG: REPLACE COMBINATION METER ASSEMBLY
OK: REPLACE ABS AND TRACTION ACTUATOR ASSEMBLY