Inspection Procedure
- INSPECT COMBINATION METER ASSEMBLY
- Disconnect the C11 connector.
- Measure the resistance according to the value(s) in COMBINATION METER ASSEMBLY (RESISTANCE)
.
Standard resistance
COMBINATION METER ASSEMBLY (RESISTANCE)Tester connection Condition Specified condition C11-40 - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in COMBINATION METER ASSEMBLY (VOLTAGE)
.
Standard voltage
COMBINATION METER ASSEMBLY (VOLTAGE)Tester connection Condition Specified condition C11-1 - Body ground Always 10 to 14 V C11-21 - Body ground Ignition switch ACC or ON 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER ASSEMBLY