FixVault

Inspection Procedure

  1. INSPECT COMBINATION METER ASSEMBLY 
    1. Disconnect the C11 connector.
    2. Measure the resistance according to the value(s) in COMBINATION METER ASSEMBLY (RESISTANCE)  .

      Standard resistance 

      COMBINATION METER ASSEMBLY (RESISTANCE)

      Tester connection Condition Specified condition
      C11-40 - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in COMBINATION METER ASSEMBLY (VOLTAGE)  .

      Standard voltage 

      COMBINATION METER ASSEMBLY (VOLTAGE)

      Tester connection Condition Specified condition
      C11-1 - Body ground Always 10 to 14 V
      C11-21 - Body ground Ignition switch ACC or ON 10 to 14 V
      Fig 1: Inspecting Combination Meter Assembly
      G04466599Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE COMBINATION METER ASSEMBLY