FixVault

Service Data

2UZ-FE COOLING - SERVICE DATA

Thermostat
Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift at 95°C (203°F) 10 mm (0.39 in.) or more
Radiator cap
Relief valve opening pressure Standard 93 to 123 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi)
Minimum 78 kPa (0.8 kgf/cm2 ,11.4 psi)