FixVault

Service Data

Sliding roof 

SLIDING ROOF - SERVICE DATA

Difference in level between sliding roof weatherstrip and roof panel
Front end and rear end 0 +-1.5 mm (0 +- 0.059 in.)
Corner of rear side 0 +- 2.0 mm (0 +- 0.079 in.)
Difference in level between sliding roof glass and roof panel front end and rear end
Front end and rear end 6.7 +- 0.7 mm (0.264 +- 0.028 in.)