Air Fuel Ratio Sensor Relay: Inspection

  1. INSPECT AIR FUEL RATIO SENSOR RELAY 
    1. Inspect A/F relay
      1. Using an ohmmeter, measure the resistance between the terminals.
    Fig 1: Identifying Air Fuel Ratio Sensor Relay Terminals
    G04996556Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.

    Resistance 

    TESTER CONNECTION SPECIFIED CONDITION

    Tester Connection Specified Condition
    1F-1 - 1C-6 10 kΩ or higher
    1F-1 - 1C-6 Below 1Ω (Apply battery voltage to terminals 1D-5 and 1H-2)

    If the result is not as specified, replace the engine room junction block assembly.