Crankshaft Position Sensor: Inspection
- INSPECT CRANKSHAFT POSITION SENSOR
- Using an ohmmeter, measure the resistance between the terminals.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
STANDARD RESISTANCETemperature Specified Condition Cold 985 to 1,600 Ω Hot 1,265 to 1,890 Ω NOTE: "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122°F) and "Hot" is from 50 to 100°C (122 to 212°F).If the resistance is not as specified, replace the sensor.
- Using an ohmmeter, measure the resistance between the terminals.