Inspection Procedure
WARNING: This page is about a different car, the 2006 Toyota Corolla and 2005 Toyota Corolla. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK CAN BUS LINE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT)
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED VALUETester Connection Condition Specified value Result D1-6 (CANH) - D1-14 (CANL) IG switch OFF 54 to 69 Ω OK D1-6 (CANH) - D1-14 (CANL) IG switch OFF 69 Ω or higher NG-A D1-6 (CANH) - D1-14 (CANL) IG switch OFF Below 54 Ω NG-B - NG-A: CHECK CAN MAIN BUS LINE FOR DISCONNECTION (SEE CHECK CAN MAIN BUS LINE FOR DISCONNECTION )
- NG-B: CHECK CAN BUS LINES FOR SHORT CIRCUIT (SEE CHECK CAN BUS LINES FOR SHORT CIRCUIT )
- OK: GO TO NEXT STEP
- CHECK CAN BUS LINE (CAN-H) FOR SHORT TO +B
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED VALUETester Connection Condition Specified value D1-6 (CANH) - D1-16 (BAT) IG switch OFF 1 MΩ or higher - NG: CHECK CAN BUS LINE (CAN-H) FOR SHORT TO +B (SEE CHECK CAN BUS LINE (CAN-H) FOR SHORT TO +B )
- OK: GO TO NEXT STEP
- CHECK CAN BUS LINE (CAN-L) FOR SHORT TO +B
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED VALUETester Connection Condition Specified value D1-14 (CANL) - D1-16 (BAT) IG switch OFF 1 MΩ or higher - NG: CHECK CAN BUS LINE (CAN-L) FOR SHORT TO +B (SEE CHECK CAN BUS LINE (CAN-L) FOR SHORT TO +B )
- OK: GO TO NEXT STEP
- CHECK CAN BUS LINE (CAN-H) FOR SHORT TO GND
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED VALUETester Connection Condition Specified value D1- (CG) - D1-6 (CANH) IG switch OFF 3 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: CHECK CAN BUS LINE (CAN-H) FOR SHORT TO GND (SEE CHECK CAN BUS LINE (CAN-H) FOR SHORT TO GND )
- OK: GO TO NEXT STEP
- CHECK CAN BUS LINE (CAN-L) FOR SHORT TO GND
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED VALUETester Connection Condition Specified value D1-4 (CG) - D1 -14 (CANL) IG switch OFF 3 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: CHECK CAN BUS LINE (CAN-L) FOR SHORT TO GND (SEE CHECK CAN BUS LINE (CAN-L) FOR SHORT TO GND )
- OK: GO TO NEXT STEP
HOW TO PROCEED WITH TROUBLESHOOTING (SEE HOW TO PROCEED WITH TROUBLESHOOTING )