FixVault

Charging System (3MZ-FE): Generator: Removal

  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 
  2. REMOVE V (COOLER COMPRESSOR TO CRANKSHAFT PULLEY) BELT NO. 1  (See REMOVAL )
  3. REMOVE GENERATOR ASSEMBLY 
    1. Remove wire harness clamp [A].
    2. Disconnect generator connector [B].
      Fig 1: Locating Generator Connector
      G05239641Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Open the terminal cap, remove the nut and disconnect generator wire [C].
    4. Loosen bolts A and B.
    5. Loosen bolt C to lessen the tension of the V belt.
      Fig 2: Locating Bolts
      G05239642Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    6. Remove bolts A and B, and the generator.
      Fig 3: Locating Bolts And Generator
      G05239643Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002