FixVault

Abs Main Relay: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. INSPECT ABS MAIN RELAY (ABS NO.1 RELAY, ABS NO.2 RELAY) 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 1: Inspecting ABS Main Relay (ABS No. 1 Relay, ABS No. 2 Relay)
      G05202732Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      Terminal 1 - Terminal 2 100 Ω
      Terminal 3 - Terminal 5 10 kΩ or higher (No Continuity)
    2. Apply battery voltage between terminals 1 and 2.
    3. Measure the resistance according to the value(s) in the table below.

      Resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      Terminal 3 - Terminal 5 Below 1 Ω