Abs Main Relay: Inspection
WARNING: This page is about a different variant/trim than selected.
- INSPECT ABS MAIN RELAY (ABS NO.1 RELAY, ABS NO.2 RELAY)
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition Terminal 1 - Terminal 2 100 Ω Terminal 3 - Terminal 5 10 kΩ or higher (No Continuity) - Apply battery voltage between terminals 1 and 2.
- Measure the resistance according to the value(s) in the table below.
Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition Terminal 3 - Terminal 5 Below 1 Ω
- Measure the resistance according to the value(s) in the table below.