FixVault

Inspection Procedure

  1. PERFORM ACTIVE TEST BY INTELLIGENT TESTER (OPEN DOOR WARNING LIGHT) 
    1. Connect the intelligent tester to the DLC3.
    2. Check that the open door warning light operates using ACTIVE TEST (see DATA LIST / ACTIVE TEST  ).

    OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE 

    NG: GO TO NEXT STEP 

  2. CHECK COMBINATION METER CIRCUIT 

    NG: REPLACE COMBINATION METER ASSEMBLY 

    OK: GO TO NEXT STEP 

  3. CHECK WIRE HARNESS (BODY ECU - COMBINATION METER ASSEMBLY) 

    NG: REPAIR OR REPLACE HARNESS AND CONNECTOR 

    OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE