  1. INSPECT TRANSMISSION REVOLUTION SENSOR (NT) 
    1. Disconnect the sensor connector from the transmission.
    2. Measure the resistance of the sensor.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1-2 20°C (68°F) 560 to 680 Ω
      Fig 1: Identifying Transmission Revolution Sensor Connector Terminals (NT)
      G05197082Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT TRANSMISSION REVOLUTION SENSOR (SP2) 
    1. Disconnect the sensor connector from the transmission.
    2. Measure the resistance of the sensor.

    Standard resistance 

    RESISTANCE SPECIFICATION

    Tester Connection Condition Specified Condition
    1 - 2 20°C (68°F) 560 to 680 Ω
    Fig 2: Identifying Transmission Revolution Sensor Connector Terminals (SP2)