Front Door Lock: Inspection
- INSPECT FRONT DOOR LOCK ASSEMBLY LH
- Apply battery voltage and inspect the door lock motor operation, as shown in the illustration and table.
Standard
MEASURING CONDITION CHARTMeasuring condition Specified Condition Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1Lock Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4Unlock If the result is not as specified, replace the door lock assembly.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Door Lock Position Specified Condition 7 - 9 Lock Below 1 Ω - OFF - 7 - 10 Unlock Below 1 Ω If the result is not as specified, replace the door lock assembly.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Door Lock Position Specified Condition 7 - 8 Lock Below 1 Ω - OFF - 7 - 9 Unlock Below 1 Ω If the result is not as specified, replace the door lock assembly.
- Apply battery voltage and inspect the door lock motor operation, as shown in the illustration and table.
- INSPECT FRONT DOOR LOCK ASSEMBLY RH
- Apply battery voltage and inspect the door lock motor operation, as shown in the illustration and table.
Standard
MEASURING CONDITION CHARTMeasuring condition Specified Condition Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1Lock Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4Unlock If the result is not as specified, replace the door lock assembly.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Door Lock Position Specified Condition 6 - 8 Lock Below 1 Ω - OFF - 5 - 8 Unlock Below 1 Ω If the result is not as specified, replace the door lock assembly.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Door Lock Position Specified Condition 7 - 8 Lock 10 kΩ or higher - OFF - 7 - 8 Unlock Below 1 Ω If the result is not as specified, replace the door lock assembly.
- Apply battery voltage and inspect the door lock motor operation, as shown in the illustration and table.