FixVault

Starter Relay: Inspection

  1. INSPECT STARTER RELAY ASSEMBLY 
    1. Check the starter relay resistance.
      1. Using an ohmmeter, measure the resistance between the terminals.

        Resistance 

        STARTER RELAY ASSEMBLY

        Tester Connection Specified Condition
        3 - 5 10 kΩ or higher
        3 - 5 Below 1 Ω (Apply battery voltage to terminals 1 and 2)

        If the result is not as specified, replace the starter relay.

        Fig 1: Checking Starter Relay Resistance
        G05193473Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002