FixVault

Inspection Procedure

  1. INSPECT FUSE (DOME) 
    1. Remove the DOME fuse from the engine room junction block and relay block.
    2. Measure the resistance of the fuses.

      Standard resistance: Below 1 Ω 

    NG : REPLACE FUSE 

    OK : GO TO NEXT STEP 

  2. CHECK WIRE HARNESS (CERTIFICATION ECU- BATTERY AND BODY GROUND) 
    1. Disconnect the S11 ECU connector.
    2. Measure the voltage of the wire harness side connector.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      S11-18 (IG) - Body ground Power switch OFF Below 1 V
      Power switch ON (IG) 10 to 14 V
      S11-1 (+B1) - Body ground Always 10 to 14 V
    3. Measure the resistance of the wire harness side connector.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition
      S11-17 (E) - Body ground Below 1 Ω

    NG : REPAIR OR REPLACE HARNESS AND CONNECTOR 

    Fig 1: Identifying S11 ECU Connector Terminal
    G04476125Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK : REPLACE CERTIFICATION ECU