FixVault

Monitor Strategy

MONITOR STRATEGY

Related DTCs P0420: Bank 1 catalyst is deteriorated
Required sensors/components Main:
A/F sensor, heated oxygen sensor
Related:
Mass airflow meter, engine coolant temperature sensor, engine speed sensor, intake air temperature sensor
Frequency of operation Once per driving cycle
Duration 30 seconds
MIL operation 2 driving cycles
Sequence of operation None