FixVault

Knock Sensor, Intake Manifold: Inspection

  1. INSPECT KNOCK SENSOR 
    1. Measure the resistance of the sensor.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition
      1 (Ground) - 2 (Output) 120 to 280 kΩ at 20°C (68°F)

      If the result is not as specified, replace the knock sensor.

    Fig 1: Inspecting Knock Sensor
    G05183850Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002