FixVault

Camshaft Timing Oil Control Valve Assembly: Inspection

  1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY 
    1. Measure the resistance of the oil control valve.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition
      1 (+B) - 2 (GND) 6.9 to 7.9 Ω at 20°C(68°F)

      If the result is not as specified, replace the oil control valve assembly.

      Fig 1: Measuring Resistance Of Oil Control Valve
      G05183802Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the operation.
      1. Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

        OK 

        TERMINALS SPECIFIED CONDITION CHART

        Condition Specified Condition
        Battery positive (+) voltage is applied Valve moves in black arrow direction shown in illustration
        Battery positive (+) voltage Is cut off Valve moves in white arrow direction shown in illustration
        Fig 2: Checking Operation - Spool Valve
        G05184258Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        NOTE: Check that the spool valve is not stuck.

        HINT:

        The spool valve may not return if foreign objects are caught in it. This may cause subtle pressure leaks to the advance side, and a DTC may be set.