FixVault

Knock Sensor, Intake Manifold: Inspection

  1. INSPECT KNOCK SENSOR 
    1. Check the resistance.
      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard 

        STANDARD REFERENCE CHART

        Tester Connection Specified Condition
        1 (Ground) - 2 (Output) 120 to 280 kΩ at 20°C (68°F)

        If the result is not as specified, replace the knock sensor.

        Fig 1: Measuring Resistance Between Terminals
        G05198023Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.