FixVault

Monitor Strategy

MONITOR STRATEGY

Related DTCs P0125: Insufficient engine coolant temperature for closed-loop fuel control
Required Sensors/Components (Main) Thermostat, cooling system
Required Sensors/Components (Related) Engine coolant temperature sensor and mass air flow meter
Frequency of Operation Continuous
Duration 56 seconds: Closed-loop enable temperature - 8.34°C (15°F) or more
98 seconds: Closed-loop enable temperature -19.45 to - 8.34°C (35 to 15°F)
1200 seconds: Less than closed-loop enable temperature - 19.45°C (35°F)
MIL Operation 2 driving cycles
Sequence of Operation P0100 - P0103 (MAF sensor)
P0110 - P0113 (IAT sensor)
P0115 - P0118 (ECT sensor)