Inspection Procedure
- READ VALUE OF DATA LIST (ACCUMULATOR)
- Connect Techstream to the DLC3.
- Turn the ignition switch to OFF.
- Depress the brake pedal more than 20 times.
- Turn the ignition switch to the ON position.
- Select the Data List mode on Techstream.
ABS/VSC/TRAC
ABS/VSC/TRAC - DATA LISTTester Display Measurement Item/Range Normal Condition Accumulator Sensor Accumulator pressure sensor reading/min.: 0 V, max.: 5 V 3.58 to 5 V - Confirm whether the accumulator output voltage is normal.RESULT REFERENCE
Result Proceed To Output value normal A Output value not normal B
B: REPLACE MASTER CYLINDER SOLENOID
A: Go To Next Step
- READ VALUE OF DATA LIST (MASTER CYLINDER PRESSURE SENSOR)
- Turn the ignition switch to OFF.
- Depress the brake pedal more than 20 times.
- Install a brake pedal effort gauge (SST), and bleed air.
- Connect Techstream to the DLC3.
- Turn the ignition switch to the ON position.
- Select the Data List mode on Techstream.
ABS/VSC/TRAC
ABS/VSC/TRAC - DATA LISTTester Display Measurement Item/Range Normal Condition Diagnostic Note Master Cylinder Sensor 1 Master cylinder pressure sensor 1 reading/min.: 0 V, max.: 5 V 0.3 to 1.9 V
With pedal pressure of 49 N (5 kgf, 11 lbf)Front brake pressure: 770 to 1280 kpa (7.9 to 13.1 kgf/cm2 , 112 to 186 psi) - Check that the master cylinder output value is in the Normal Condition range.
OK: Master cylinder pressure sensor value is in the Normal Condition.
NG: REPLACE MASTER CYLINDER SOLENOID
OK: Go To Next Step
- RECONFIRM DTC
- Clear the DTCs (See DTC CHECK/CLEAR ).
- Turn the ignition switch to OFF.
- Depress the brake pedal more than 20 times.
- Turn the ignition switch to the ON position.
- Wait until the pump motor stops.
- Depress the brake pedal and release it.
- Wait for 25 minutes.
- Check if the same DTCs are recorded.DTC OUTPUT REFERENCE
Result Proceed To DTC output A DTC not output B
B: END
A: REPLACE MASTER CYLINDER SOLENOID