Inspection Procedure
- INSPECT DLC3 (TS TERMINAL VOLTAGE)
- Turn the ignition switch to the ON position.
- Measure the voltage.
Standard
VOLTAGE SPECIFICATIONTester Connection Specified Condition D4-12 (TS) - D4-4 (CG) 10 to 14 V - Turn the ignition switch to OFF.
NG: Go to step 3
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - DLC3)
- Disconnect the skid control ECU connector.
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified condition S1-24 (TS) - D4-12 (TS) Below 1 Ω - Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified Condition S1-24 (TS) - Body ground 10 kΩ or higher - Reconnect the skid control ECU connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: REPLACE MASTER CYLINDER SOLENOID
- CHECK HARNESS AND CONNECTOR (BODY GROUND - DLC3)
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified condition D4 (CG) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- Measure the resistance.
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - DLC3)
- Disconnect the skid control ECU connector.
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified condition S1-24 (TS) - D4-12 (TS) Below 1 Ω - Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified Condition S1-24 (TS) - Body ground 10 kΩ or higher - Reconnect the skid control ECU connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: REPLACE MASTER CYLINDER SOLENOID