FixVault

Typical Malfunction Thresholds

TYPICAL MALFUNCTION THRESHOLDS

Either of following conditions 1 or 2 met -
1. Frequency that both of following conditions (a) and (b) met 5 times or more
(a) Engine rpm - Target engine rpm Less than -100 rpm, or more than 200 rpm
(b) Vehicle condition Stop after vehicle was driven by 6 mph (10 km/h) or more
2. Frequency that both of following conditions (c) and (d) met Once
(c) Engine rpm - Target engine rpm Less than -100 rpm, or more than 200 rpm
(d) IAC flow rate learning value 7 L/sec. or less, or 1.1 L/sec. or more