FixVault

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Tilt & Telescopic / Data List.
    5. Check the values by referring to the table below.

      Tilt & Telescopic 

      TILT & TELESCOPIC - DATA LIST

      Tester Display Measurement Item/Range Normal Condition
      Tilt Position Current tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Position Current telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Return Position Memorized tilt return position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Return Position Memorized telescopic return position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Memory Pos 1 Tilt data of memory position 1/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Memory Pos 1 Telescopic data of memory position 1/ min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Memory Pos 2 Tilt data of memory position 2/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Memory Pos 2 Telescopic data of memory position 2/ min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Memory Pos 3 Tilt data of memory position 3/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Memory Pos 3 Telescopic data of memory position 3/ min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Up Limit Uppermost tilt position/Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      Tilt Up Limit Position Uppermost tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Down Limit Lowermost tilt position/Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      Tilt Down Limit Position Lowermost tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Short Limit Shortest telescopic position/Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      Telesco Short Limit Pos Shortest telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Telesco Long Limit Longest telescopic position/Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      Telesco Long Limit Pos Longest telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges)
      Tilt Up Switch Input state of tilt up by manual switch/ ON or OFF ON: Tilt up activated by manual switch
      OFF: Tilt up not activated by manual switch
      Tilt Up SW (CAN) Input state of tilt up by manual switch/ ON or OFF ON: Tilt up activated by manual switch
      OFF: Tilt up not activated by manual switch
      Tilt Down Switch Input state of tilt down by manual switch/ON or OFF ON: Tilt down activated by manual switch
      OFF: Tilt down not activated by manual switch
      Tilt Down SW (CAN) Input state of tilt down by manual switch/ON or OFF ON: Tilt down activated by manual switch
      OFF: Tilt down not activated by manual switch
      Telesco Short Switch Input state of telescopic short by manual switch/ON or OFF ON: Telescopic short activated by manual switch
      OFF: Telescopic short not activated by manual switch
      Telesco Short SW (CAN) Input state of telescopic short by manual switch/ON or OFF ON: Telescopic short activated by manual switch
      OFF: Telescopic short not activated by manual switch
      Telesco Long Switch Input state of telescopic long by manual switch/ON or OFF ON: Telescopic long activated by manual switch
      OFF: Telescopic long not activated by manual switch
      Telesco Long SW (CAN) Input state of telescopic long by manual switch/ON or OFF ON: Telescopic long activated by manual switch
      OFF: Telescopic long not activated by manual switch
      T&T Manual SW Data Voltage data of manual switch/min.: 0 V, max.: 5 V Neutral position: Below 0.2 V
      Tilt up: 1.67 to 2.13 V
      Tilt down: 0.54 to 0.74 V
      Telescopic contract: 1.08 to 1.40 V
      Telescopic extend: 2.22 to 2.77 V
      S/B Mem 1 Tilt and telescopic memory position 1/ Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      S/B Mem 2 Tilt and telescopic memory position 2/ Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      S/B Mem 3 Tilt and telescopic memory position 3/ Not Mem or Mem Not Mem: Position not memorized
      Mem: Position memorized
      T&T Autoaway Function Auto away/return function/ON or OFF ON: Auto away/return function allowed
      OFF: Auto away/return function prohibited
      Power Source Voltage Voltage data of power supply/min.: 0 V, max.: 20 V Actual power supply voltage 11 to 14 V
      Freeze Speed Info Vehicle speed data/min.: 0 km/h (0 mph), max.: 255 km/h (158 mph) Actual vehicle speed
      IG Switch(CAN) Communication state of engine switch/ ON or OFF ON: Communication normal
      OFF: Communication interrupted
      IG Switch Input state of engine switch/ON or OFF ON: Input signal normal
      OFF: Input signal interrupted
      Key Code Confirm(CAN) Communication state of key code confirmation signal/ON or OFF ON: Communication normal
      OFF: Communication interrupted
      Receive from Meter Communication state of combination meter signal/OK or Interruption OK: Communication normal Interruption: Communication interrupted
      Receive from Seat ECU Communication state of position control ECU signal/OK or Interruption OK: Communication normal Interruption: Communication interrupted
      Receive from Combi Communication state of combination switch ECU signal/OK or Interruption OK: Communication normal Interruption: Communication interrupted
      J/B Communication state of main body ECU signal/OK or Interruption OK: Communication normal Interruption: Communication interrupted
      B/B Communication state of optional after parts ECU signal/OK or Interruption OK: Communication normal Interruption: Communication interrupted
      The Number of DTCs Number of diagnostic trouble codes / min.: 0, max.: 255 Actual number of diagnostic trouble codes
  2. PERFORM ACTIVE TEST 

    HINT:

    Using the Techstream to perform Active Tests allows relays, VSVs actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Tilt & Telescopic / Active Test.
    5. Check the values by referring to the table below.

      Tilt & Telescopic 

      TILT & TELESCOPIC - ACTIVE TEST REFERENCE

      Tester Display Test Part Control Range
      Tilt Operation Tilt operation Up/Down
      Telesco Operation Telescopic operation Long/Short