  1. INSPECT SHIFT SOLENOID VALVE SLT 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SLT.

      Fig 1: Inspecting Shift Solenoid Valve SLT
      G06011465Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
      NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK: 

      The solenoid makes an operating sound  .

      If the operation cannot be done as specified, replace the shift solenoid valve SLT.

  2. INSPECT SHIFT SOLENOID VALVE SL1 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SL1.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
      NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK: 

      The solenoid makes an operating sound  .

      Fig 2: Inspecting Shift Solenoid Valve SL1
      G06043167Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      If the operation cannot be done as specified, replace the shift solenoid valve SL1.

  3. INSPECT SHIFT SOLENOID VALVE DSL 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      Solenoid Connector (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 13 Ω

      If the value is not as specified, replace the shift solenoid valve DSL.

      Fig 3: Inspecting Shift Solenoid Valve DSL
      G06043168Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
      NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK: 

      The solenoid makes an operating sound  .

      If the operation cannot be done as specified, replace the shift solenoid valve DSL.

  4. INSPECT SHIFT SOLENOID VALVE SL2 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SL2.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
      Fig 4: Inspecting Shift Solenoid Valve SL2
      G06011469Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK: 

      The solenoid makes an operating sound  .

      If the operation cannot be done as specified, replace the shift solenoid valve SL2.

  5. INSPECT SHIFT SOLENOID VALVE S4 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      Solenoid Connector (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15 Ω
      Fig 5: Inspecting Shift Solenoid Valve S4
      G06043170Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      If the value is not as specified, replace the shift solenoid valve S4.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
      NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      OK: 

      The solenoid makes an operating sound  .

      If the operation cannot be done as specified, replace the shift solenoid valve S4.