Stop Light Control Relay: Inspection
- INSPECT STOP LIGHT CONTROL RELAY ASSEMBLY
- Disconnect the S31 stop light control relay assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Standard VoltageTester Connection Condition Specified Condition S31-2 (STP) - Body ground Brake pedal released Below 1 V S31-2 (STP) - Body ground Brake pedal depressed 11 to 14 V S31-6 (+B) - Body ground Always 11 to 14 V If the result is not as specified, there is a malfunction on the wire harness side.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Standard ResistanceTester Connection Condition Specified Condition S31-4 (GND) - Body ground Always Below 1Ω If the result is not as specified, there is a malfunction on the wire harness side.