Inspection Procedure
- INSPECT FUSE (STOP, IGN, IG2)
- Remove the STOP and IGN fuses from the instrument panel junction block.
- Remove the IG2 fuse from the engine room No. 1 relay block.
- Measure the resistance of the fuses.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK: Go to next step
- INSPECT IG2 RELAY
- Remove the IG2 relay from the instrument panel junction block.
- Measure the resistance of the relay.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 3 - 5 10 kΩ or higher Below 1 Ω (when battery voltage is applied to terminals 1 and 2) NG: REPLACE IG2 RELAY
OK: Go to next step
- INSPECT STOP LIGHT SWITCH
- Remove the stop light switch.
- Measure the resistance of the switch.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 2 Not pushed Below 1 Ω 3 - 4 Pushed 1 - 2 Pushed 10 kΩ or higher 3 - 4 Not pushed NG: REPLACE STOP LIGHT SWITCH
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next step
- CHECK WIRE HARNESS (SWITCH - BATTERY)
- Disconnect the A3 switch connector.
- Measure the voltage of the wire harness side connector.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition A3-2 - Body ground Always 11 to 14 V A3-4 - Body ground Ignition switch ON NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: Go to next step
- CHECK WIRE HARNESS (ECM - BATTERY)
- Disconnect the A9 ECM connector.
- Turn the ignition switch ON.
- Measure the voltage of the wire harness side connector.
Standard voltage
for 2GR-FE
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition A9-35 (ST1-) - Body ground Depressed 11 to 14 V A9-36 (STP) - Body ground Released A9-35 (ST1-) - Body ground Released Below 1 V A9-36 (STP) - Body ground Depressed for 2AR-FE
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition A9-39 (ST1-) - Body ground Depressed 11 to 14 V A9-29 (STP) - Body ground Released A9-39 (ST1-) - Body ground Released Below 1 V A9-29 (STP) - Body ground Depressed NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: REPLACE ECM