FixVault

Outer Mirror Switch: Inspection

  1. INSPECT OUTER MIRROR SWITCH ASSEMBLY 
    1. With the left/right adjustment switch set to L: Measure the resistance of the mirror switch.

      Standard resistance (for left side) 

      RESISTANCE SPECIFIED CONDITION

      Tester Connection Switch Condition Specified Condition
      4 (MLV) - 8 (B)
      6 (M+) - 7 (E)
      UP Below 1 Ω
      OFF 10 kΩ or higher
      4 (MLV) - 7 (E)
      6 (M+) - 8 (B)
      DOWN Below 1 Ω
      OFF 10 kΩ or higher
      5 (MLH) - 8 (B)
      6 (M+) - 7 (E)
      LEFT Below 1 Ω
      OFF 10 kΩ or higher
      5 (MLH) - 7 (E)
      6 (M+) - 8 (B)
      RIGHT Below 1 Ω
      OFF 10 kΩ or higher

      If the result is not as specified, replace the switch assembly.

    2. With the left/right adjustment switch set to R: Measure the resistance of the mirror switch.

      Standard resistance (for right side) 

    RESISTANCE SPECIFIED CONDITION

    Tester Connection Switch Condition Specified Condition
    3 (MRV) - 8 (B)
    6 (M+) - 7 (E)
    UP Below 1 Ω
    OFF 10 kΩ or higher
    3 (MRV) - 7 (E)
    6 (M+) - 8 (B)
    DOWN Below 1 Ω
    OFF 10 kΩ or higher
    2 (MRH) - 8 (B)
    6 (M+) - 7 (E)
    LEFT Below 1 Ω
    OFF 10 kΩ or higher
    2 (MRH) - 7 (E)
    6 (M+) - 8 (B)
    RIGHT Below 1 Ω
    OFF 10 kΩ or higher