Air Pump (for Bank 1) 

2UZ-FE EMISSION CONTROL - SERVICE DATA

Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.44 to 1.0 Ω
1 - Body ground
2 - Body ground
Always 10 kΩ or higher

Air Pump (for Bank 2) 

2UZ-FE EMISSION CONTROL - SERVICE DATA

Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.4 to 1.0 Ω
1 - Body ground
2 - Body ground
Always 10 kΩ or higher

Air Switching Valve 

2UZ-FE EMISSION CONTROL - SERVICE DATA

Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground
5 - Body ground
Always 1 MΩ or higher

Purge VSV 

2UZ-FE EMISSION CONTROL - SERVICE DATA

Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω
1 - Body ground
2 - Body ground
Always 10 MΩ or higher