FixVault

Service Data

PURGE VSV

Tester Connection Specified Condition
1 - 2 23 to 26Ω at 20 °C (68 °F)
1 - Body ground 10 MΩ or higher
2 - Body ground 10 MΩ or higher
AIR FUEL RATIO SENSOR

Tester Connection Specified Condition
1 (HT) - 2 (+B) 1.8 to 3.4 Ω at 20 °C (68 °F)
1 (HT) - 4 (AF-) 10 kΩ or higher
OXYGEN SENSOR (FOR BANK 1 SENSOR 2)

Tester Connection Specified Condition
1 (HT) - 2 (+B) 11 to 16 Ω at 20 °C (68 °F)
1 (HT) - 4 (E1) 10 kΩ or higher
OXYGEN SENSOR (FOR BANK 2 SENSOR 2)

Tester Connection Specified Condition
1 (HT) - 2 (+B) 11 to 16 Ω at 20 °C (68 °F)
1 (HT) - 4 (E1) 10 kΩ or higher