FixVault

Service Data

VOLTAGE INVERTER (STANDARD VOLTAGE)

Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected N20-1 (GND) - N20-2 (+B) Engine switch on (IG) 11 to 14 V
N20-1 (GND) - Body ground Always Below 1 V
VOLTAGE INVERTER (STANDARD VOLTAGE)

Connector Condition Tester Connection Switch Condition Specified Condition
Component with harness connected N19-5 (AC1) - N19-11 (AC2) Engine switch on (IG)
Main switch on
AC 120 V