FixVault

Diagnosis System

  1. CHECK DLC3 
    1. Check the DLC3. Refer to GENERAL INFORMATION .
  2. INSPECT BATTERY VOLTAGE 
    1. Measure the battery voltage.

      Standard voltage

      11 to 14 V

      If the voltage is below 11 V, recharge or replace the battery before proceeding to the next step.