FixVault

Service Data

MAF METER

Tester Connection Condition Specified Condition
4 (THA) - 2 (E2) -20°C (-4°F) 12.5 k to 16.9 kΩ
20°C (68°F) 2.19 k to 2.67 kΩ
60°C (140°F) 0.50 k to 0.68 kΩ
CAMSHAFT TIMING OIL CONTROL VALVE

Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 6.9 to 7.9 Ω
ENGINE COOLANT TEMPERATURE SENSOR

Tester Connection Condition Specified Condition
1 - 2 Approx. 20°C (68°F) 2.32 k to 2.59 kΩ
Approx. 80°C (176°F) 0.310 k to 0.326 kΩ
THROTTLE BODY

Tester Connection Condition Specified Condition
1 (M-) - 2 (M+) 20°C (68°F) 0.3 to 100 Ω
ACCELERATOR PEDAL

Tester display Accelerator pedal released Accelerator pedal depressed
Accelerator position No. 1 0.5 to 1.1 V 2.6 to 4.5 V
Accelerator position No. 2 1.2 to 2.0 V 3.4 to 4.7 V
KNOCK SENSOR

Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 120 to 280 kΩ
IGNITION RELAY NO. 2

Tester Connection Condition Specified Condition
IG2 MAIN fuse Always Below 1 Ω
1C-1 - 1B-8 When battery voltage is not applied to terminals 1B-6 and 1B-7 10 kΩ or higher
When battery voltage is applied to terminals 1B- 6 and 1B-7 Below 1 Ω
EFI RELAY

Tester Connection Condition Specified Condition
EFI No. 1 fuse Always Below 1 Ω
1C-1 - 1B-4 When battery voltage is not applied to terminals 1B-2 and 1B-3) 10 kΩ or higher
When battery voltage is applied to terminals 1B- 2 and 1B-3) Below 1 Ω
CIRCUIT OPENING RELAY

Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω
FUEL PUMP RELAY

Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω
AIR FUEL RATION SENSOR (FOR BANK 1 SENSOR 1)

Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω
AIR FUEL RATION SENSOR (FOR BANK 2 SENSOR 1)

Tester Connection Condition Specified Condition
1 (HA2A) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω
HEATED OXYGEN SENSOR (FOR BANK 1 SENSOR 2)

Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
HEATED OXYGEN SENSOR (FOR BANK 2 SENSOR 2)

Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
A/F SENSOR HEATER RELAY

Tester Connection Condition Specified Condition
A/F fuse Always Below 1 Ω
1C-1 - 1A-4 When battery voltage is not applied to terminals 1A-2 and 1A-3 10 kΩ or higher
When battery voltage is applied to terminals 1A- 2 and 1A-3 Below 1 Ω
FUEL PRESSURE CONTROL VALVE RELAY

Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω
SPARK PLUG

Recommended spark plug DENSO made: SK20HR11
Correct electrode gap for new spark plug 1.0 to 1.1 mm (0.0394 to 0.0433 in.)
Maximum electrode gap for used spark plug 1.3 mm (0.0512 in.)
Standard insulation resistance 10 MΩ or more