FixVault

Purge Valve: Inspection: Inspection

  1. INSPECT PURGE VSV 
    Fig 1: Measuring Resistance Between Purge SVV Terminals
    GTY211749Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Check the resistance.
      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance

        Tester Connection Specified Condition
        1 - 2 23 to 26 Ω at 20°C (68°F)

        If the resistance is not as specified, replace the purge VSV.

    2. Check the operation.
      Fig 2: Checking If Air Does Not Flow From Port E To F
      GTY227862Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. Check that air does not flow from port E to F.
      2. Apply battery voltage across the terminals.
        Fig 3: Checking If Air Flows From Port E To F
        GTY211358Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Check that air flows from port E to F.

        If the operation is not as specified, replace the purge VSV.