FixVault

Problem Symptoms Table

HINT: 

Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.

CLOCK ASSEMBLY (W/ OCCUPANT CLASSIFICATION SYSTEM)

Symptom Suspected Area Refer To
Clock does not operate at all. Fuse (ACC, ECU-B) -
Clock Assembly Refer to REMOVAL
Clock display illumination malfunction Wire Harness or Connector -
Combination Meter Refer to REMOVAL
Clock Assembly Refer to REMOVAL
Clock loses or gains time. Clock Assembly Refer to REMOVAL
TELLTALE LIGHT ASSEMBLY (W/O OCCUPANT CLASSIFICATION SYSTEM)

Symptom Suspected Area Refer To
Clock does not operate at all. Fuse (ACC, ECU-B) -
Telltale Light Assembly Refer to REMOVAL
Clock display illumination malfunction Wire Harness or Connector -
Combination Meter Refer to REMOVAL
Telltale Light Assembly Refer to REMOVAL
Clock loses or gains time. Telltale Light Assembly Refer to REMOVAL