FixVault

Service Data

SKID CONTROL BUZZER

Measurement Condition Specified Condition
Battery positive (+) voltage → Terminal 1 Skid control buzzer sounds
Battery negative (-) → Terminal 2
A-TRAC SWITCH

Tester Connection Switch Condition Specified Condition
5 - 8 Pressed Below 1 Ω
Not Pressed 10 kΩ or higher
VSC OFF SWITCH

Tester Connection Switch Condition Specified Condition
3 - 4 Pressed Below 1 Ω
Not Pressed 10 kΩ or higher
DOWNHILL ASSIST CONTROL SWITCH

Tester Connection Switch Condition Specified Condition
3 - 4 Pressed Below 1 Ω
Not Pressed 10 kΩ or higher