Power Vent Window Motor Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (POWER QUARTER WINDOW SWITCH - BODY GROUND)
- Disconnect the power quarter window switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D3-5 (E) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (BATTERY - POWER QUARTER WINDOW SWITCH)
- Measure the voltage according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Voltage
Tester Connection Switch Condition Specified Condition D3-1 (B) - D3-5 (E) Ignition switch ON 11 to 14 V D3-1 (B) - D3-5 (E) Ignition switch off Below 1 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Power Quarter Window Switch)
NG → CHECK FOR ALL HARNESSES, CONNECTORS AND COMPONENTS CONNECTED TO P/VENT FUSE
OK: Go to next step
- Measure the voltage according to the value(s) in the table below.
- INSPECT POWER QUARTER WINDOW SWITCH
- Remove the power quarter window switch.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition D3-1 (B) - D3-3 (OPEN) Open position → Close position Below 1 Ω → 10 kΩ or higher D3-1 (B) - D3-4 (CLS) Open position → Close position 10 kΩ or higher → Below 1 Ω D3-3 (OPEN) - D3-5 (E) Open position → Close position 10 kΩ or higher → Below 1 Ω D3-4 (CLS) - D3-5 (E) Open position → Close position Below 1 Ω → 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Power Quarter Window Switch)
NG → REPLACE POWER QUARTER WINDOW SWITCH
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (POWER QUARTER WINDOW SWITCH - POWER VENT WINDOW MOTOR)
- Disconnect the power vent window motor assembly LH and RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D3-3 (OPEN) - K15-1 (OPEN) Always Below 1 Ω D3-4 (CLS) - K15-2 (CLS) Always Below 1 Ω D3-3 (OPEN) - L28-1 (OPEN) Always Below 1 Ω D3-4 (CLS) - L28-2 (CLS) Always Below 1 Ω D3-3 (OPEN) - Body ground Always 10 kΩ or higher D3-4 (CLS) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK REAR QUARTER POWER WINDOW CONTROL SYSTEM
- Check the operation of the rear quarter power window control system.
Result
Result Proceed to The rear quarter power window control system operates normally. A The power vent window motor assembly LH does not operate normally. B The power vent window motor assembly RH does not operate normally. C
B → See step 6
C → See step 8
A → See step 7
- Check the operation of the rear quarter power window control system.
- REPLACE POWER VENT WINDOW MOTOR ASSEMBLY LH. Refer to REMOVAL
- USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING
- REPLACE POWER VENT WINDOW MOTOR ASSEMBLY RH. Refer to REMOVAL