Inspection [12/2013 - 11/2016]: Procedure

  1. INSPECT KNOCK CONTROL SENSOR 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 25 °C (77 °F) 120 to 280 kΩ

      If the result is not as specified, replace the knock control sensor.

      GTY432602Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Knock Control Sensor)